EXPOSURE TO NON-IONIZING RADIATION OF AREA IN URBAN ZONE OF THE BANJA LUKA CITY

By
Zoran Popović ,
Zoran Popović

PSI Institute for protection and ecology of the Republic of Srpska , Banja Luka , Bosnia and Herzegovina

Predrag Ilić ,
Predrag Ilić
Contact Predrag Ilić

PSI Institute for protection and ecology of the Republic of Srpska , Banja Luka , Bosnia and Herzegovina

Ranko Mirošljević ,
Ranko Mirošljević

PSI Institute for protection and ecology of the Republic of Srpska , Banja Luka , Bosnia and Herzegovina

Suzana Gotovac-Atlagić
Suzana Gotovac-Atlagić

Faculty of Science, University of Banja Luka , Banja Luka , Bosnia and Herzegovina

Abstract

Intensity of electromagnetic pollution is followed by rapid increasing of new telecommunication technologies over the years. In order to prevent enlarged exposed of general population with doses of electromagnetic radiation above allowed for general population, living as well as working environment around antenna systems should be tested. Using sophisticated measurement equipment we measure intensity of electric field emitted from base station located at shopping center in urban zone of the Banja Luka city. Theoretical estimation of exposition was preceded to measurement procedure, resulting in mapping of exposure at different altitude around antenna system. This thorough investigation of electromagnetic pollution will become a part of typical systematic testing of high frequency non-ionizing radiation pollution. Tested area, around shopping center, where are located educational institution and sports center is found safe from emitted radiation.

References

1.
Poljak D. Human Exposure to ElectromagneticFields. 2003.
2.
Poljak D, Šarolić A, Roje V. Humaninteraction with the electromagnetic field radiatedfrom a cellular base station antennas,EMC. In: EUROPE 2002 International Symposiumon Electromagnetic Compatibility. 2002.
3.
Poljak D. Human exposure to the radiation from antenna system of base stations- dosimetry of emitted field. Sigurnost. 2012;54(2):173.
4.
Šuka DS, Ožegović PD. Calculation of electromagnetic radiation parameters emitted from base stations of mobile telecommunication via plane wave method. INFOTEH-JAHORINA. 2016;15 (262.
5.
Prša M, Juhas A, Kasaš-Lazetić K, Đurić N, Milutinov M. Estimation of electric field intensity vector around mobile GSM base station. “ZRENJANIN. 2004;3”, XLVIIIETRANVol.II (196.
6.
Wojcik D. Evaluation of near field of the GSM base station antennas in urban environment. Journal of telecommunications and information technology. 2003;41.
7.
Higashiyama J, Tarusawa Y. Evaluating RF filed intensity in mobile base station environments. Technology Reports. 2015;3 (27.

Citation

This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. 

Article metrics

Google scholar: See link

The statements, opinions and data contained in the journal are solely those of the individual authors and contributors and not of the publisher and the editor(s). We stay neutral with regard to jurisdictional claims in published maps and institutional affiliations.